PS2 Redundant

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

RHD-6400P

FEATURES
  • Protections:OVP/OCP/SCP/OPP
Dimension
183(D)*153.4(W)*213.2(H)
Application (Form Factor)
  • PS2 Redundant
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 90 264 Vac
Input Frequency Range 47 63 Hz
Maximum Input Current *Io=100%;Low Line
*Io=100%;High Line
7
2.5
A
Leakage Current *per module
3.5 mA
Inrush Current *Vin=110Vac,Cold start/25℃
*Vin=220Vac,Cold start/25℃
*per module
65
125
A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V -5V 5VSB
400W 35A 28A 20A 1A 0.8A 2A
Load Regulation +/-5% +/-5% +/-5% +/-6% +/-5% +5/-7%
Ripple & Noise 60 60 100 100 100 60

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature *refer derating curve 0 40
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS B
Surge EN61000-4-5 DM:+/-1KV
CM:+/-2KV
Harmonic Currents EN 61000-3-2 CLASS D

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
181870 Hours
Efficiency Io=100%;Vin=115Vac 68 %
Power Density *per module
3.63 W/in3
File description File name
CB CB
CCC CCC
FCC FCC
MANUAL Manual
TUV TUV
DRAWING DRAWING
MTBF MTBF
MTBF MTBF(RoHS)