2U Redundant

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

R1S2-5380V4V

FEATURES
  • 1+1 Redundant Application
  • Support I2C
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections:OVP/SCP
  • Operation Altitude:5000meters
Dimension
207(D)*85(W)*84(H)
Application (Form Factor)
  • 2U Redundant
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 90 264 Vac
Input Frequency Range 47 63 Hz
Maximum Input Current *Io=100%;Low Line
*Io=100%;High Line
5.5
2.5
A
Leakage Current *per module 3.5 mA
Inrush Current *Vin=115Vac,Cold start/25℃
*Vin=230Vac,Cold start/25℃
*per module
15
30
A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V 5VSB
380W 20A 20A 30A 0.5A 2.5A
Load Regulation +/-5% +/-5% +/-5% +/-10% +/-5%
Ripple & Noise 50 50 120 120 50

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature 0 40
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5 DM:+/-1KV
CM:+/-2KV
Harmonic Currents EN 61000-3-2 CLASS D

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
223678 Hours
Efficiency Io=100%;Vin=230Vac 82 %
Power Density *per module 11.16 W/in3
File description File name
CB CB
CB CB
CCC CCC
CE CE(Radiation)
FCC FCC
TUV TUV
DRAWING DRAWING
MTBF MTBF(ROHS)