1U Redundant Module

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

MRT-6300P-R

FEATURES
  • N+1 Redundant Application(Module)
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections:OPP/SCP
Dimension
153(D)*120(W)*41.4(H)
Application (Form Factor)
  • 1U Redundant Module
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 90 264 Vac
Input Frequency Range 47 63 Hz
Maximum Input Current *Io=100%;Low Line
*Io=100%;High Line
6
3
A
Leakage Current 3.5 mA
Inrush Current *Vin=110Vac,Cold start/25℃
*Vin=220Vac,Cold start/25℃
60
80
A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V -5V 5VSB
300W 25A 18A 16A 0.5A 0.5A 2A
Load Regulation +/-5% +/-5% +/-7% +/-10% +/-10% +/-5%
Ripple & Noise 50 50 120 150 150 60

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature 0 40
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS B
Surge EN61000-4-5 DM:+/-1KV
CM:+/-2KV
Harmonic Currents EN 61000-3-2 CLASS D

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
101461 Hours
Efficiency Io=100%;Vin=115Vac 63 %
Power Density 6.47 W/in3
File description File name
CB CB
CB CB
CCC CCC
CE CE (Radiation)
FCC FCC
DRAWING DRAWING