1U Single

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

MP1T-1AF0V48

FEATURES
  • Medical safety(2 x MOPP)
  • Fan Reverse Option
  • Standard Dimension -1U
  • Protections:OVP/SCP/OPP
Dimension
265(D)*103(W)*40(H)
Application (Form Factor)
  • 1U Single
  • Medical
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 90 264 Vac
Input Frequency Range 47 63 Hz
Maximum Input Current *Io=100%;Vin=90Vac
*Io=100%;Vin=180Vac
20
10
A
Leakage Current 0.35 mA
Inrush Current *Vin=115Vac,Cold start/25℃
*Vin=230Vac,Cold start/25℃
20
40
A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
48V
1600W 33.3A(180-264V)
30A(90-140V)
Load Regulation +/-5%
Ripple & Noise 200

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature 0 50
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS B
Surge EN61000-4-5 DM:+/-1KV
CM:+/-2KV
Harmonic Currents EN 61000-3-2 CLASS D

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
127000 Hours
Efficiency Io=100%;Vin=230Vac 90 %
Power Density 24.05 W/in3
File description File name
DRAWING DRAWING