1U Redundant Module

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

M1U-2AF0T54

FEATURES
  • 80 PLUS TITANIUM
  • N+1 Redundant Application(Module)
  • Support PMBUS 1.2
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections:OPP/OVP/SCP/OCP/OTP/UVP
  • Operation Altitude:5000meters
Dimension
300(D)*50.5(W)*40(H)
Application (Form Factor)
  • 1U Redundant Module
  • Redundant Module-Slim Type
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 90 264 Vac
Input Frequency Range 47 63 Hz
Maximum Input Current *Io=100%;Low Line
*Io=100%;High Line
14.5
10.5
A
Leakage Current 3.5 mA
Inrush Current 50 A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
54V 12VSB
1600W 29.3A(200-264V)
22.22A(110-132V)
18.51A(90-110V)
*Inlet-C16 / OPTION
2.1A
Load Regulation +/-5% +/-5%
Ripple & Noise 220 120

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature *refer derating curve 0 60
Relative Humidity Non-condensing 10 85 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5 DM:+/-1KV
CM:+/-2KV
Harmonic Currents EN 61000-3-2 CLASS D

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
156816 Hours
Efficiency Io=50%;Vin=230Vac 96 %
Power Density 43.26 W/in3
File description File name