2U Redundant

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

DR1T2-5180V2V

FEATURES
  • 1+1 Redundant Application
  • LVDC Application
  • Support PMbus 1.2
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections:OVP/SCP
  • Operation Altitude:5000meters
Dimension
245(D)*54.5(W)*84.6(H)
Application (Form Factor)
  • 2U Redundant
  • Redundant-Slim Type
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range -36 -72 Vdc
Input Frequency Range Hz
Maximum Input Current *Io=100%;Low Line
*Io=100%;High Line
6
3.5
A
Leakage Current *per module mA
Inrush Current *Vin=-48Vdc,Cold start/25℃
*per module
30 A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V 5VSB
180W 16A 16A 15A 0.3A 3A
Load Regulation +/-5% +/-5% +/-5% +/-10% +/-5%
Ripple & Noise 50 50 120 120 50

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature 0 50
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5 DM:+/-1KV
CM:+/-2KV
Harmonic Currents

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
253618 Hours
Efficiency Io=100%;Vin=-48Vdc 85 %
Power Density *per module 8.85 W/in3
File description File name
DRAWING DRAWING
MTBF MTBF(MIL-HDBK-217F)