CRPS Redundant

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

BZRH2-5550V2V

FEATURES
  • 1+1 Redundant Application
  • Support PMBus 1.2
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections:OVP/OCP/SCP/UVP/OTP/Fan Lock
  • Operation Altitude:5000meters
Dimension
245(D)*76(W)*84(H)
Application (Form Factor)
  • CRPS Redundant
  • 2U Redundant
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 21 36 Vdc
Input Frequency Range
Maximum Input Current *Io=100%;Vin=21Vdc
*Io=100%;Vin=31Vdc
38
20
A
Leakage Current
Inrush Current *Vin=24Vdc,Cold start/25℃
*per module
25 A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V 5VSB
550W 20A 20A 45A 0.5A 3.5A
Load Regulation +/-5% +/-5% +/-5% +/-10% +/-5%
Ripple & Noise 50 50 120 120 50

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature 0 50
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5
DM:+/-1KV
CM:+/-2KV
Harmonic Currents

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
230352 Hours
Efficiency Io=50%;Vin=24V
(one power unit)
84 %
Power Density per module 16.58 W/in3
File description File name
MTBF MTBF (RoHS)(WP1.2)