1U Redundant Module

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

BUSP-2750K2

FEATURES
  • Ultra LVDC Application
  • 80PLUS PLATINUM
  • N+1 Redundant Application(Module)
  • Wide Temperature Design: Operates from -40°C to 70°C.
  • Fan Reverse Option
  • Protections:OVP/OCP/SCP/UVP/OTP/Fan Lock
  • Operation Altitude:5000meters
Dimension
360(D)*38(W)*40(H)
Application (Form Factor)
  • 1U Redundant Module
  • Redundant Module-Slim Type
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 18 36 Vdc
Input Frequency Range Hz
Maximum Input Current *Io=100%;Low Line
*Io=100%;High Line
30
33
A
Leakage Current mA
Inrush Current 35 A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
12V 5VSB
750W 62.5A(28-36Vdc)
33.3A(18-28Vdc)
3A
Load Regulation +/-5% +/-5%
Ripple & Noise 120 50

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature *refer derating curve -40 70
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5
DM:+/-1KV
CM:+/-2KV
Harmonic Currents

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
157604 Hours
Efficiency Io=50%;Vin=28Vdc 94 %
Power Density 22.47 W/in3