2U Redundant

ZIPPY is capable of producing small quantities of multiple sizes and changing specifications according to customers' needs, so as to meet customers' demands at any time.

BR2G-5460V4V

FEATURES
  • 1+1 Redundant Application
  • Ultra LVDC Application
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections:OVP/OCP/SCP
  • Operation Altitude:5000meters
Dimension
276(D)*101(W)*82(H)
Application (Form Factor)
  • 2U Redundant
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 18 36 Vdc
Input Frequency Range Hz
Maximum Input Current *Io=100%;Vin=18Vdc
*Io=100%;Vin=36Vdc
32
16
A
Leakage Current *per module mA
Inrush Current *Vin=24Vdc,Cold start/25℃
*per module
30 A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V 5VSB
460W 25A 25A 37A 0.8A 3.5A
Load Regulation +/-5% +/-5% +/-5% +/-10% +/-5%
Ripple & Noise 50 50 120 120 50

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature 0 40
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5 DM:+/-1KV
CM:+/-2KV
Harmonic Currents

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
194074 Hours
Efficiency Io=100%;Vin=24Vdc 80 %
Power Density *per module 9.42 W/in3
File description File name
CB CB
CE CE(Radiation)
FCC FCC
TUV TUV
DRAWING DRAWING
MTBF MTBF(RoHS)