CRPS Module

ZIPPY可依客戶需求進行少量多樣化生產及規格化的變更,隨時滿足客人需求。

ZRL-2CB0K2

FEATURES
  • 80 PLUS PLATINUM
  • N+1 Redundant Application
  • Support PMBus 1.2
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections:OVP/OCP/SCP/UVP/OTP/Fan Lock
  • Operation Altitude:5000meters
Dimension
265(D)*73.5(W)*40(H)
Application (Form Factor)
  • CRPS Module
  • 1U Redundant Module
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 180 264 Vac
Input Frequency Range 47 63 Hz
Maximum Input Current *Io=100%;Vin=180Vac 16
A
Leakage Current 3.5 mA
Inrush Current *Vin=230Vac,Cold start/25℃
30 A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
12V 12VSB
3200W 261A 2.1A
Load Regulation +/-5% +/-5%
Ripple & Noise 120 120

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature *refer derating curve 0 60
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5
DM:+/-1KV
CM:+/-2KV
Harmonic Currents EN 61000-3-2 CLASS D

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
145437 Hours
Efficiency Io=100%;Vin=230Vac 89 %
Power Density 67.36 W/in3
檔案說明 檔案名稱