CRPS Redundant

ZIPPY可依客戶需求進行少量多樣化生產及規格化的變更,隨時滿足客人需求。

ZRH2-5BG0K2H

FEATURES
  • 80 PLUS PLATINUM
  • 1+1 Redundant Application
  • Support PMBus 1.2
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections OVP/OCP/SCP/UVP/OTP/Fan Lock
  • Dual Input Voltage Application
Dimension
260(D)*153(W)*41.3(H)
Application (Form Factor)
  • CRPS Redundant
  • 1U Redundant
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range Dual Input 90
180
264
310
Vac
Vdc
Input Frequency Range AC Input 47 63 Hz
Maximum Input Current *Io=100%;Vin=90Vac
*Io=100%;Vin=180Vac
16 A
Leakage Current Acin Only 3.5 mA
Inrush Current *per module 35 A
OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V 5VSB
2700W 36A 31A
ACin : 225A(230-264V)
       208A(180-230V)
       116.7A(115-127V)
       100A(90-115V)
 
DCin : 225A(230-310Vdc)
       208A(180-230Vdc)
0.5A 3.5A
Load Regulation +/-5% +/-5% +/-5% +/-10% +/-5%
Ripple & Noise 50 50 180 120 50

*+5V and +3.3V total output max:210W

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature *refer derating curve 0 60
Relative Humidity Non-condensing 10 85 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5
DM:+/-1KV
CM:+/-2KV
Harmonic Currents EN 61000-3-2 CLASS D

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
184703 Hours
Efficiency Io=100%;Vin=230Vac
(one power unit)
86 %
Power Density per module 81.41 W/in3
檔案說明 檔案名稱