ATX-PS2

ZIPPY可依客戶需求進行少量多樣化生產及規格化的變更,隨時滿足客人需求。

HG2-6300P

FEATURES
  • Support - AC cable pull back from rear side(Option)
  • Smart Fan Speed Control
  • Standard Dimension -ATX/PS2
  • Protections:OVP/SCP/OPP
Dimension
140(D)*150(W)*86(H)
Application (Form Factor)
  • ATX-PS2
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 90 264 Vac
Input Frequency Range 47 63 Hz
Maximum Input Current *Io=100%;Low Line
*Io=100%;High Line
7
3.5
A
Leakage Current 3.5 mA
Inrush Current *Vin=115Vac,Cold start/25℃
*Vin=230Vac,Cold start/25℃
65
125
A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V -5V 5VSB
300W 35A 28A 22A 0.8A 0.5A 2A
Load Regulation +/-5% +/-5% +7/-5% +/-5% +/-5% +/-5%
Ripple & Noise 50 50 120 150 150 50

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature -10 50
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS B
Surge EN61000-4-5
DM:+/-1KV
CM:+/-2KV
Harmonic Currents EN 61000-3-2 CLASS D

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
170211 Hours
Efficiency Io=100%;Vin=115Vac 70 %
Power Density 2.72 W/in3
檔案說明 檔案名稱
CB CB
CB CB-62368
CCC CCC
CE CE
FCC FCC
MANUAL Manual-English
MANUAL Manual-Chinese
TUV TUV
TUV TUV(62368-1)
DRAWING DRAWING
MTBF MTBF(RoHS)