2U Redundant

ZIPPY可依客戶需求進行少量多樣化生產及規格化的變更,隨時滿足客人需求。

BMTW2-5600V3V

FEATURES
  • 1+1 Redundant Application
  • Ultra LVDC Application
  • Fan Reverse Option
  • Smart Fan Speed Control
  • Protections:OVP/OCP/SCP
Dimension
300(D)*101(W)*84(H)
Application (Form Factor)
  • 2U Redundant
INPUT CHARACTERISTICS
Parameter Notes & Conditions Min. Type. Max Units
Operating Voltage Range 19 36 Vdc
Input Frequency Range Hz
Maximum Input Current *Io=100%;Low Line
*Io=100%;High Line
45
21
A
Leakage Current *per module mA
Inrush Current *Vin=24Vdc,Cold start/25℃
*per module
50 A

 

OUTPUT CHARACTERISTICS
WATTAGE OUTPUT
5V 3.3V 12V -12V 5VSB
600W 32A 36A 50A 0.8A 3.5A
Load Regulation +/-5% +/-5% +/-5% +/-5% +/-5%
Ripple & Noise 50 50 120 120 50

 

ENVIRONMENTAL SPEC.
Parameter Notes & Conditions Min. Type. Max. Units
Temperature 0 40
Relative Humidity Non-condensing 20 80 %
Emissions EN55032
FCC Part15
CLASS A
Surge EN61000-4-5 DM:+/-1KV
CM:+/-2KV
Harmonic Currents

 

GENERAL SPEC.
Parameter Notes & Conditions Min. Type. Max Units
MTBF Io=100%;Ta=25℃
per MIL-HDBK-217F
142528 Hours
Efficiency Io=100%;Vin=24Vdc 80 %
Power Density *per module 9.42 W/in3
檔案說明 檔案名稱
MTBF MTBF(RoHS)