【Open Frame】DG1X2-1060V12
60W
Server ,Workstation ,Storage System
190x106x39.5(mm)
7.48x4.17x1.56(inch)
VOLTAGE: 39-72VDC full range.FREQUENCY: The input frequency is 0 HZ (DC).Steady-state current:2A/1A at any low/high range input voltage.Inrush current:3Amps @ 48 VDC High Frequency Peak Amplitudes lasting less than 100uS
* TEMPERATURE RANGE:OPERATING 0℃~70℃, STORAGE –20℃~80℃ * HOLD UP TIME: When DC source shutdown DC output must be maintain 1msec in regulation limit at. normal input voltage (DC -48V) * EFFICIENCY:78% (+/-2%) typical 78%±2%,AT FULL LOAD -48Vdc and Load condition : 12V/5A * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1mS * OVER POWER PROTECTION: 120~170% * OVER VOLTAGE PROTECTION: +12V→13.2V~15.0V * SHORT CIRCUIT PROTECTION: +12V * SAFETY: TO MEET UL&CUL, TUV, CCC *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module