Products

Search:

DZRH2-5800V2V(800W)

DIMENSION:245x76x84(mm) / 9.65 x2.99x3.31(inch)
DC INPUT VOLTAGE, (RATING: -36~-72Vdc, NORMAL: -48Vdc)
DC INRUSH CURRENT 25 amps max. @ -48VDC INPUT
INPUT CURRENT:10A (RMS) FOR 115 VAC / 5A (RMS) FOR 230 VAC
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

DZRP2-5600V2V(600W)

DIMENSION:245x76x84(mm) / 9.65 x2.99x3.31(inch)
DC INPUT VOLTAGE, (RATING: -36~-72Vdc, NORMAL: -48Vdc)
DC INRUSH CURRENT 25 amps max. @ -48VDC INPUT
INPUT CURRENT:10A (RMS) FOR 115 VAC / 5A (RMS) FOR 230 VAC
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

USP2-5A00K2H(1000W)

DIMENSION:425x81.5x41.3(mm) / 16.7 x3.21x1.63(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:12A (RMS) FOR 115 VAC / 6.5A (RMS) FOR 230 VAC
INRUSH CURRENT:40A MAX. FOR 115 VAC PER MODULE / 80 MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

MP1P-5300G(300W)

DIMENSION:170x81.5x40.3(mm) / 6.69 x3.21x1.59(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:5A (RMS) FOR 115 VAC / 2.5A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30 MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

MHG2-5500G(500W)

DIMENSION:140x150x86(mm) / 5.51 x5.91x3.39(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:8A (RMS) FOR 115 VAC / 4A (RMS) FOR 230 VAC
INRUSH CURRENT:20A MAX. FOR 115 VAC PER MODULE / 40A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

P1H-5701G(700W)

DIMENSION:225x100x40.5(mm) / 8.86 x3.94x1.59(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:10A (RMS) FOR 115 VAC / 5A (RMS) FOR 230 VAC
INRUSH CURRENT:40A MAX. FOR 115 VAC PER MODULE / 80A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

P1H-5700G(700W)

DIMENSION:225x100x40.5(mm) / 8.86 x3.94x1.59(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:10A (RMS) FOR 115 VAC / 5A (RMS) FOR 230 VAC
INRUSH CURRENT:40A MAX. FOR 115 VAC PER MODULE / 80A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

R1S2-5300K0V(300W)

DIMENSION:207x85x84(mm) / 8.15 x3.35x3.31(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:5A (RMS) FOR 115 VAC / 2.5A (RMS) FOR 230 VAC
INRUSH CURRENT:20A MAX. FOR 115 VAC PER MODULE / 40A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

M1K2-5AE0K2H(1500W)

DIMENSION:410x106x41.3(mm) / 16.41 x4.17x1.59(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:15A (RMS) FOR 115 VAC / 10A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

M1R2-5800K2H(800W)

DIMENSION:295x106x41.3(mm) / 11.61 x4.17x1.59(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:12A (RMS) FOR 115 VAC / 6A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

M1R2-5700K2H(700W)

DIMENSION:295x106x41.3(mm) / 11.61 x4.17x1.59(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:12A (RMS) FOR 115 VAC / 6A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

R1U2-5600K2H(600W)

DIMENSION:260x106x41.3(mm) / 10.23 x4.17x1.59(inch)
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:8.5A (RMS) FOR 115 VAC / 4A (RMS) FOR 230 VAC
INRUSH CURRENT:30A MAX. FOR 115 VAC PER MODULE / 60A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

 1           

keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module