【CRPS Redundant】ZRH2-5AF0K2H
1600W
260x153x41.3(mm)
0x0x0(inch)
"VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZINPUT CURRENT:10.5A (RMS) FOR 110 VAC /8.5A (RMS) FOR 220 VAC INRUSH CURRENT:35A MAX.(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)PFC: UP TO THE TARGET OF 99% @230V, FULL LOAD.( ONE UNIT POWER SUPPLY)."
"* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -40℃~70℃ * HOLD UP TIME:WHEN POWER SHUTDOWN ALL THE DC OUTPUT VOLTAGE MUST BE MAINTAIN 10mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE(70%LOAD) * THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 86%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING (one power unit).* LEAKAGE CURRENT: 3.5mA. MAX. AT NOMINAL VOLTAGE 240 VAC AND 60Hz * REMOTE ON/OFF CONTROL * OVER POWER PROTECTION:110~160% MAX * OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.3V, +12V→13.5~15V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * OVER CURRENT PROTECTION: +12V:110~165% * SAFETY: MEET 60950 UL&CUL, TUV, CCC ,UL/EN/IEC 62368 * WARNING METHOD: FALUT LED, TTL * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS."
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module