【Medical】MHG2-5400G
400W
Server ,Workstation ,PCs
140x150x86(mm)
5.51x5.91x3.39(inch)
VOLTAGE: 100~240VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:6A (RMS) FOR 115 VAC / 3A (RMS) FOR 230 VAC. INRUSH CURRENT:20A MAX. FOR 115 VAC / 40A MAX. FOR 230 VAC(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT) PFC: UP TO THE TARGET OF 95%@110V
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN ALL THE DC OUTPUT VOLTAGE MUST BE MAINTAIN 16mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE (70% LOAD) * THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 87%, MEA
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module