【Micro Redundant】M1Y2-5300G2H
300W
Server ,Workstation ,Storage System ,IPC
275x106x41.3(mm)
10.83x4.17x1.63(inch)
VOLTAGE: 90~264VAC FULL RANGEFREQUENCY: 47~63HZINPUT CURRENT:5A (RMS) FOR 115 VAC / 2.5A (RMS) FOR 230 VACINRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 15MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * THE MAXMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE MORE THAN 86%, MEASURED AT NOMINALINPUT VOLTAGE 115V 90% LOAD OR 230V FULL LOAD * LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 240VAC * REMOTE ON/OFF CONTROL * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms * OVER POWER PROTECTION:110~180% MAX * OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.3V, +12V→13.3~15V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * OVER CURRENT PROTECTION: +12V--110~180% * SAFETY: MEET UL&CUL, TUV, CCC * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module