【Micro Redundant】M1R2-5300V0H
300W
Server ,Workstation ,Storage System ,IPC
295x106x41.3(mm)
11.61x4.17x1.63(inch)
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:6A (RMS) FOR 115 VAC 3A (RMS) FOR 230 VAC INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE 30A MAX. FOR 230 VAC PER MODULE
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 15MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 82%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING * LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC * REMOTE ON/OFF CONTROL * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms * OVER POWER PROTECTION:110~150% MAX * OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.1V, +12V→12.8~13.9V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * OVER CURRENT PROTECTION: +12V--110~150% * SAFETY: MEET UL&CUL, TUV, CCC * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module