【Open Frame】Q1N-3400K
400W
Server ,Workstation ,Storage System ,IPC
199x92x43(mm)
7.83x3.62x1.69(inch)
VOLTAGE: 90~264VAC FULL RANGEFREQUENCY: 47~63HZINPUT CURRENT:6A (RMS) FOR 115 VAC3A (RMS) FOR 230 VACINRUSH CURRENT:30 AMPS @ 230 VAC (AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
‧TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃ ‧HOLD UP TIME:16mS MINIMUM AT 115V FULL LOAD ‧EFFICIENCY:90% TYPICAL,AT FULL LOAD 230V ‧REMOTE ON/OFF CONTROL ‧LEAKAGE CURRENT: INPUT LEAKAGE CURRENT FROM LINE TO GROUND WILL BE LESS THAN 3.5MA RMS. MEASUREMENT WILL BE MADE AT 240 VAC AND 60HZ. ‧POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS ‧OVER POWER PROTECTION:110~160% MAX ‧OVER VOLTAGE PROTECTION: +12V→ 13.2~15V ‧SHORT CIRCUIT PROTECTION: +12V, +5VSB ‧SAFETY : TO MEET UL, CUL, TUV, CCC *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module