【N+1 Redundant】MTW4-5F50V3H
1550W
Server ,Workstation ,Storage System ,IPC ,Communication ,Networking
340x422x43(mm)
13.39x16.61x3.27(inch)
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT (PER POWER MODULE):24 / 11 AMPSMAXIMUM AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT (PER POWER MODULE):40/60A MAX. FOR 115/230VAC (25℃)
* TEMPERATURE RANGE:OPERATING 0℃~45℃, STORAGE -20℃~80℃ * HOLD UP TIME:16mS IN REGULATOIN LIMIT AT 90VAC INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE * EFFICIENCY:>80% AT 115VAC, 30%~100% MAX LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500Ms * OVER POWER PROTECTION: 110~160% * OVER VOLTAGE PROTECTION:+3.3V→3.9V~4.7V,+5V→5.7V~6.5V ,+12V→12.8 V~13.9V * OVER CURRENT PROTECTION: +5V,+12V,+3.3V 110~ 160% AT FULL LOAD * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V * REMOTE ON / OFF CONTROL * BALANCE LOAD SHARING DESIGN * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION * ISOLATION: BUILT-IN THE POWER MODULE * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL * COOLING:38*28mm, TWO DC FAN (PER MODULE) * EMI NOISE FILTER: FCC CLASS B , CISPR 22 CLASS B * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC) * SAFETY:TO MEET UL, TUV, CB IEC60950 *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module