【N+1 Redundant】MTW4-5H80V3V
1780W
Server ,Workstation ,Storage System ,IPC ,Communication
300x101.2x166(mm)
11.81x3.98x6.54(inch)
VOLTAGE: 90V ~ 264VAC (WITH ± 10% TOLERANCE) FREQUENCY: 47Hz ~ 63Hz INPUT CURRENT: INPUT CURRENT:27/12A MAX AT ANY LOW/HIGH INPUT VOLTAGE INRUSH CURRENT: 40A MAX. FOR 115 VAC PER MODULE; 60A MAX. FOR 230 VAC PER MODULE POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% @ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC 61000-3-2
* TEMPERATURE RANGE: OPERATING: 0℃~ 45℃, STORAGE: -20℃~ 80℃ * HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE * EFFICIENCY: TYPICAL >80% AT 115V, 30~100% MAX LOAD * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms * OVER POWER PROTECTION: 110~160% * OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.9~4.7V, +12V→12.8~13.9V * OVER CURRENT PROTECTION: +5V, +12V, +3.3V, LIMITED CURRENT IS OVER 110~160% FOR EACH OUTPUT CURRENT AT EACH POWER MODULE * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V * WARMING METHOD: BUZZER SOUND, TTL * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION * BALANCE LOAD SHARING DESIGN * REMOTE ON/OFF CONTROL * SAFETY: TO MEET UL, CUL, TUV, CCC * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module