【Micro Redundant】DM1U2-5750V4H
750W
Server ,Workstation ,Storage System ,IPC ,Communication ,Networking
355x106x41.3(mm)
13.98x4.17x1.63(inch)
VOLTAGE:-40 ~ -72VDC FREQUENCY: DC STEADY-STATE CURRENT: 24 / 14A MAXIMUN AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT: 10A MAX. @-48VDC INPUT (AT 25DEGREES AMBIENT COLD START)
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STOREAGE -20℃~80℃ * HOLD UP TIME:1mS MIN. * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE * EFFICIENCY(PER SET):POWER SUPPLY EFFICIENCY TYPICAL 85% AT 115V, 12V/54A 5VSB/0.4A; POWER SUPPLY EFFICIENCY TYPICAL 88% AT 230V, 12V/54A 5VSB/0.4A. * OVER POWER PROTECTION: 110~150% * OVER VOLTAGE PROTECTION:+3.3V→5.5V~6.5V,+5V→7.5V~9V,+12V→15.5 V~17.5V * OVER CURRENT PROTECTOIN: +5V, +12V, +3.3V, 110~150% * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V * REMOTE ON / OFF CONTROL * REMOTE SENSING DESIGN * BALANCE LOAD SHARING DESIGN * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION * ISOLATION: BUILT-IN THE POWER MODULE * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL * COOLING:40*28mm DC FAN (MODULE) * EMI NOISE FILTER: FCC CLASS A , CISPR 22 CLASS A * SAFETY:MEET UL, CUL, TUV *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module