【PS2+】GU2-5A50V
1050W
Server ,Workstation ,Storage System
160x150x86(mm)
6.3x5.91x3.39(inch)
VOLTAGE:90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:14 (RMS) FOR 120 VAC / 7A (RMS) FOR 230 VAC INRUSH CURRENT:40A MAX. FOR 120 VAC / 80A MAX. FOR 230 VAC PFC CAN REACH THE TARGET OF 95% @230VAC, FULL LOAD
* TEMPERATURE RANGE:OPERATING 0℃~40℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 12mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * EFFICIENCY:TYPICAL 80-85% AT 25℃ 115V FULL LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS * OVER POWER PROTECTION:TRIP POINT TOTAL POWER MIN. 110%, MAX. 150% * OVER VOLTAGE PROTECTION:+5V→5.8V~6.7V, 3.3V→3.6V~4.3V, +12V→13.2V~15V * OVER CURRENT PROTECTOIN: +3.3V→37.4~51A, +5V→37.4~51A, +12V→93.5~127A * SHORT CIRCUIT :+5V、-5V、+12V、-12V、+3.3V * RESTART AFTER PROTECTION * LEAKAGE CURRENT: 1.5MA MAX. AT NOMINAL VOLTAGE VAC * EMI NOISE FILTER : FCC CLASS B , CISPR22 CLASS B * SAFETY : TO MEET UL, CUL, TUV, CCC * REMOTE ON/OFF CONTROL *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module