【Mini 1U Single】P1S-5200V
200W
Server ,Workstation ,Storage System ,IPC
150x81.5x40.3(mm)
5.9x3.21x1.59(inch)
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:3A (RMS) FOR 115 VAC / 1.5A (RMS) FOR 230 VAC INRUSH CURRENT:35A MAX. FOR 115 VAC / 70A MAX. FOR 230 VAC
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:16mS MINIMUM AT 115V FULL LOAD * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND * EFFICIENCY:Power supply efficiency typical 80%(+/-2%) at 230Vin and Load condition: 12V10.43A;5V/7.33A;3.3V/7.33A;-12V/0.21A;5Vsb/2.17A * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1mS * OVER POWER PROTECTION:110~160% MAX * OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * SAFETY : TO MEET UL, TUV, CCC, CSA 22.2 NO 60950 * LEAKAGE CURRENT: 3.5MA MAX. AT NOMINAL VOLTAGE 264VAC *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module