【2U Single】P2H-5501V
500W
Server ,Workstation ,Storage System ,IPC
215x100x70(mm)
8.46x3.94x2.76(inch)
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:10A (RMS) FOR 115 VAC/ 5A (RMS) FOR 230 VAC INRUSH CURRENT:40A MAX. FOR 115 VAC/ 60A MAX. FOR 230 VAC
* TEMPERATURE RANGE:OPERATING 0℃~50℃ * HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE * EFFICIENCY:TYPICAL >80% AT 115VAC , FULL LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS * OVER POWER PROTECTION:110~160% MAX * OVER VOLTAGE PROTECTION:+5V→5.6V~6.5V +3.3V→3.6V~4.3V +12V→13.2V~15V * OVER CURRENT PROTECTION: +3.3V→44~64A, +5V→44~64A, +12V→44~60A * SHORT CIRCUIT PROTECTION:+5V、+12V、+3.3V、-12V、+5VSB * EMI NOISE FILTER : FCC CLASS A, CISPR22 CLASS A * SAFETY : TO MEET UL, CUL, TUV, CCC * REMOTE ON/OFF CONTROL THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE. * 3.3V & 5V REMOTE SENSING * COOLING: ONE 40mm DC FANS * MEET IEC-1000-3-2 CLASS D *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module