【Mini 1U Single】P1S-5150V
150W
Server ,Workstation ,Storage System ,IPC ,Blade server
150x81.5x40.3(mm)
5.91x3.21x1.59(inch)
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:2A (RMS) FOR 115 VAC / 1A (RMS) FOR 230 VAC INRUSH CURRENT:35A MAX. FOR 115 VAC / 70A MAX. FOR 230 VAC
* TEMPERATURE RANGE:OPERATING 0℃~50℃ * HOLD UP TIME:16mS MINIMUM AT 115V FULL LOAD * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND * EFFICIENCY:80%±2% TYPICAL,AT FULL LOAD 115Vac * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1mS * OVER POWER PROTECTION:110~170% MAX * OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, AUTO-RECOVERED: +5VSB * SAFETY : TO MEET UL, CUL, TUV, CCC * REMOTE ON/OFF CONTROL THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE. * MEET IEC-1000-3-2 CLASS D *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.