【N+1 Redundant】R3G-5950V4V
950W
Server ,Workstation ,Storage System
276x83x127(mm)
10.87x3.27x5(inch)
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:8A/3A (115 / 230 VAC) POWER MODULE INRUSH CURRENT:35/70A MAX. FOR 115/230 VAC POWER MODULE
* TEMPERATURE RANGE:OPERATING 0℃~40℃ * HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 60 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 60 SECOND * EFFICIENCY:82% TYPICAL AT 115VAC, FULL LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS * OVER POWER PROTECTION:110% ~ 180% * OVER VOLTAGE PROTECTION:+5V→5.9V~6.7V、+12V→13.0V~15.0V、+3.3V→3.9V~4.3V SHORT CIRCUIT PROTECTION:SHUT DOWN AND LATCH OFF * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B * SAFETY: TO MEET UL, CUL, TUV, CCC * REMOTE ON/OFF CONTROL THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE. * N+1 REDUNDANCY FUNCTION * HOT-SWAPPABLE FUNCTION * CURRENT/BALANCE LOAD SHARING DESIGN * +3.3V REMOTE SENSING * ISOLATION: BUILT-IN IN POWER MODULE * POWER FACTOR CORRENTION: ACTIVE (MEET IEC-1000-3-2) * COOLING: 40mm DC FANS (one module) * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module