【PS2】HU2-5860V
860W
Server ,Workstation ,Storage System
150x140x86(mm)
5.91x5.51x3.39(inch)
VOLTAGE:90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:12.0A (RMS) FOR 115 VAC / 6.0A (RMS) FOR 230 VAC INRUSH CURRENT:20A MAX. FOR 115 VAC / 40A MAX. FOR 230 VAC PFC CAN REACH THE TARGET OF 95% @230VAC, FULL LOAD
* TEMPERATURE RANGE:OPERATING 0℃~50℃ * HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 SECOND, INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND * EFFICIENCY:TYPICAL 80-85% AT 25℃ 115V FULL LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS * OVER POWER PROTECTION:TRIP POINT TOTAL POWER MIN. 130%, MAX. 170% * OVER VOLTAGE PROTECTION:+5V→5.8V~6.7V, 3.3V→3.6V~4.3V, +12V→13.2V~15V * SHORT CIRCUIT PROTECTION:+5V、-5V、+12V、-12V、+3.3V * RESTART AFTER PROTECTION * EMI NOISE FILTER : FCC CLASS B , CISPR22 CLASS B * SAFETY : UL, CUL, TUV, CCC * REMOTE ON/OFF CONTROL: THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL. DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE. *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module