【PS2+】PSM-5760V
760W
Server ,Workstation ,Storage System
160x150x86(mm)
6.3x5.91x3.39(inch)
VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 HZ INPUT CURRENT: 12 A ( RMS ) FOR 115VAC / 6A ( RMS ) FOR 230VAC INRUSH CURRENT: 20A MAX. FOR 115 VAC / 40A MAX. FOR 230 VAC PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD
* TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃ * HOLD UP TIME: WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * HUMIDITY: OPERATING:20%-80%, NON-OPERATING:10%-90% * EFFICIENCY: TYPICAL 80-85% AT 25℃ 115V FULL LOAD * OVER POWER PROTECTOIN: 130%~170% * OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.8~6.7V, +12V→13.2~15V * OVER CURRENT PROTECTION: +3.3V→29.7~40.2A, +5V→29.7~40.2A, +12V→63.7~86.2A * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V * RESTART AFTER PROTECTION: IF THE PSU IS USING AC POWER SWITCH TO CONTROL ON/OFF, IT HAS TO BE SWITCHED OFF AT LEAST FOR 5 SECONDS TO RESTART THE UNIT * SAFETY: TO MEET UL, CUL, TUV, CCC * COOLING: ONE 60 mm DC FAN *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module