【Easy Swap】GIN1-5800V4D
800W
Server ,Workstation ,Storage System ,Communication ,Networking
397x79x40(mm)
15.63x3.11x1.57(inch)
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:6A(RMS)FOR 230VAC 12A(RMS)FOR 115VAC INRUSH CURRENT:60A MAX. FOR 115 VAC PER MODULE 80A MAX. FOR 230 VAC PER MODULE
* TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16mSEC IN REGULATON LIMIT AT NORMAL INPUT VOLTAGE. * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE * EFFICIENCY:TYPICAL >80% AT 25℃115V, 20%~100% MAX LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms * OVER POWER PROTECTION:110~160% MAX * OVER VOLTAGE PROTECTION: +12V→13V~15V, +5V→5.9V~6.7V, +3.3V→3.9V~4.3V * SHORT CIRCUIT PROTECTION: +5V, +12V, -12V, +3.3V, AUTO-RECOVERED: +5VSB * RESTART AFTER PROTECTOIN: AFTER THE PROTECTION MODE(OPP/OVP) OR SHORT CIRCUIT IS REMOVED AND A POWER ON/OFF CYCLE IS INITIATED, THE POWER SUPPLY WILL RESTART. IF THE PSU IS USING AC POWER SWITCH TO CONTROL ON/OFF, IT HAS TO BE SWITCHED OFF AT LEAST FOR 5 SECONDS TO RESTART THE UNIT. * SAFETY:TO MEET UL, CUL, TUV, CCC *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module