Products

1U RedundantR1T2-5500K2H


OUTPUT WATTAGE

500W

BEST SOLUTION FOR

DIMENSION

215x106x41.5(mm)

0x0x0(inch)

INPUT SPEC

Voltage: 90~264Vac
Frequency: 47~63Hz
Input Current:8A(Low Line) /4A (High Line)
Inrush Current:30A Max
PFC: UP TO THE TARGET OF 95%@115V

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0.0 16.0 ±5% ±1% 50mV
+12V 4 42 ±5% ±1% 120mV
3.3V 0.0 16.0 ±5% ±1% 50mV
-12V 0.0 0.3 ±10% ±1% 120mV
+5VSB 0.1 3.0 ±5% ±1% 50mV
* +5V AND +3.3V Max. POWER:105W

FEATURES

*80 PLUS PLATINUM
*N+1 Redundant Application
*Support PMBus 1.2
*Fan Reverse Option
*Smart Fan Speed Control
*Protections:OVP/OCP/SCP/UVP/FAN LOCK
*Operation Altitude:5000 meters
*MTBF>285000 hours
*Wide range working temperature:0~55℃

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module