Products

1U SingleP1P-5AB0G2


OUTPUT WATTAGE

1200W

BEST SOLUTION FOR

DIMENSION

230x81.5x40.3(mm)

0x0x0(inch)

INPUT SPEC

"VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:15A (RMS) FOR 100 VAC /8A (RMS) FOR 240 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.
"

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 16 ±5% ±1% 50mV
+12V 2 100 ±5% ±1% 120mV
3.3V 0 16 ±5% ±1% 50mV
-12V 0 0.3 ±10% ±1% 120mV
+5VSB 0 3 ±5% ±1% 50mV
* +5V AND +3.3V Max. POWER:105W

FEATURES

"* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN ALL THE DC OUTPUT VOLTAGE MUST BE MAINTAIN 16mS.
Tested at 75% of maximum load and over 100-240 VAC input
* THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 85%, MEASURED AT NOMINAL INPUT VOLTAGE 115V AND FULL LOADING
* LEAKAGE CURRENT: 3.5mA. MAX. AT NOMINAL VOLTAGE 240 VAC AND 60Hz
* REMOTE ON/OFF CONTROL
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION: +5V→5.5~6.5V, +3.3V→3.7~4.3V, +12V→13.2~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V,-12V, +5VSB
* SAFETY: MEET 60950 UL&CUL, TUV, CCC ,UL/EN/IEC 62368
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
"

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module