Products

1U RedundantUSP2-5A00K2H


         

OUTPUT WATTAGE

1000W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC ,Communication ,Networking

DIMENSION

425x81.5x41.3(mm)

16.7x3.21x1.63(inch)

INPUT SPEC

VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:12A (RMS) FOR 115 VAC / 6.5A (RMS) FOR 230 VAC
INRUSH CURRENT:40A MAX. FOR 115 VAC PER MODULE / 80 MAX. FOR 230 VAC PER MODULE(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95%@115V & 90% @230V, FULL LOAD.( ONE NUIT POWER SUPPLY).

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 18 ±5% ±1% 50mV
+12V 0 83 ±5% ±1% 120mV
+3.3V 0 18 ±5% ±1% 50mV
-12V 0 0.5 ±5% ±1% 120mV
+5VSB 0 3 ±5% ±1% 50mV
The output current of +5V and +3.3V not exceed 150W Total power: 1000W (MAX) @ 230VAC 800W (MAX) @ 115VAC

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN ALL THE DC OUTPUT VOLTAGE MUST BE MAINTAIN 12mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE (70% LOAD)
* THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 86%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING
* LEAKAGE CURRENT: 3.5mA. MAX. AT NOMINAL VOLTAGE 240 VAC AND 60Hz
* REMOTE ON/OFF CONTROL
* OVER POWER PROTECTION:110~160% MAX
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.9~4.7V, +12V→13.3~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* OVER CURRENT PROTECTION: +12V:110~165%
* SAFETY: MEET 60950UL&CUL, TUV, CCC ,UL/EN/IEC 62368
* WARNING METHOD: FALUT LED, TTL
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module