Products

N+1 RedundantM1K4-7BG0V0H


 

OUTPUT WATTAGE

2700W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC ,Communication ,Networking

DIMENSION

450x219x45.5(mm)

17.72x8.62x1.79(inch)

INPUT SPEC

VOLTAGE: AC Input Voltage, Frequency and Current (Rating: 100V-240Vac, 47-63Hz, 15-8A)
FREQUENCY: 47~63HZ
INRUSH CURRENT (PER SET): 15/30 AMPS@115/230VAC
Power factor correction / Current Harmonics: PFC can reach the target of 95% @110V,full load, following the standard Of EN 61000-3-2
Efficiency(per set): Typical 83% at 115V,12V/83A,5VSB/0.1A; typical 86% at 230V,12V/83A,5VSB/0.1A

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V1 0 27 ±5% ±1% 50mV
+5V2 0 27 ±5% ±1% 50mV
+5V3 0 27 ±5% ±1% 50mV
+3.3V 0 31 ±5% ±1% 50mV
+12V 2 225 ±5% ±1% 120mV
-12V 0 0.5 ±5% ±1% 120mV
+5VSB 0.1 3 ±5% ±1% 50mV
*+5V1 AND +3.3V TOTAL MAX:210W *+5V2 AND +5V3 TOTAL MAX:270W *+5V1~+5V3 are not able to have parallel connection *Total output power not exceed:2700W(MAX)

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
* OVER POWER PROTECTION
* OVER VOLTAGE PROTECTION
* SHORT CIRCUIT PROTECTION
* SAFETY:TO MEET UL, CUL, TUV, CCC
* The power supply shall be designed to meet the following standards a. EN 61000-4-2(ESD) Criterion B, ± 4KV by contact, ±8KV by air. b. EN 61000-4-4(EFT) Criterion B, ± 1KV. c. EN 61000-4-5(SURGE) Criterion B, Line-Line ± 1KV Line-Earth ± 2KV.


* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

 DOWNLOAD
DRAWING

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module