Products

Open FrameQ1Q-1060V12


     

OUTPUT WATTAGE

60W

BEST SOLUTION FOR

Server ,Workstation

DIMENSION

137x50x32(mm)

5.39x1.97x1.26(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35/70 AMPS @115/230 VAC
(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+12V 0.1 5 ±5% ±1% 120mV
* TOTAL POWER: 60W(MAX)

FEATURES

‧TEMPERATURE RANGE:OPERATING -40℃~70℃, STORAGE -40℃~80℃
‧HOLD UP TIME:16mS MINIMUM AT 115V FULL LOAD
‧EFFICIENCY:82% TYPICAL,AT FULL LOAD 115/230V
‧LEAKAGE CURRENT: INPUT LEAKAGE CURRENT FROM LINE TO GROUND WILL BE LESS THAN 3.5MA RMS. MEASUREMENT WILL BE MADE AT 240 VAC AND 60HZ.
‧OVER POWER PROTECTION: TRIGGER POINT TOTAL POWER MIN. 66W, MAX. 96W.
‧OVER VOLTAGE PROTECTION: +12V→ 13.8~15V
‧SHORT CIRCUIT PROTECTION: +12V
‧SAFETY : TO MEET UL, CUL, TUV, CCC


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

 DOWNLOAD
DRAWING
MTBF(RoHS)

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module