Products

N+1 RedundantM1P4-6950V4H


   

OUTPUT WATTAGE

950W

BEST SOLUTION FOR

Server ,Workstation ,IPC

DIMENSION

260x359x41.8(mm)

10.24x14.13x1.65(inch)

INPUT SPEC

VOLTAGE: 90V ~ 264VAC (WITH ± 10% TOLERANCE)
FREQUENCY: 47Hz ~ 63Hz
INPUT CURRENT: 15/8A MAX AT ANY LOW/HIGH INPUT
VOLTAGE
INRUSH CURRENT: 40/60A @ 115/230VAC (25℃)
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95%
@ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC 1000-3-2

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V1 0.5 32 ±5% ±1% 50mV
+5V2 0.5 32 ±5% ±1% 50mV
+12V 6 79 ±5% ±1% 50mV
-12V 0.1 0.5 ±5% ±1% 50mV
+3.3V 0.5 25 ±5% ±1% 50mV
+5VSB 0.5 5 ±5% ±1% 50mV
REMARKS:
* +5V1, +5V2 AND +3.3V TOTAL OUTPUT MAX: 350W
* TOTAL OUTPUT MAX: 950W

FEATURES

* TEMPERATURE RANGE: OPERATING: 0℃ ~ 40℃, STORAGE: -20℃ ~ 80℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
* EFFICIENCY: TYPICAL >80% AT 115VAC FULL LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OUTPUT PROTECTION: OPP / OVP / OCP / SCP
* REMOTE ON/OFF CONTROL
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
* ISOLATION: BUILT-IN THE POWER MODULE
* SAFETY: TO MEET UL, CUL, TUV, CCC
* REMOTE SENSING DESIGN

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module