Products

2U RedundantM1X2-5550V0V


   

OUTPUT WATTAGE

550W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

240x101x84(mm)

9.45x3.98x3.31(inch)

INPUT SPEC

VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
INPUT CURRENT: 4.0 A (RMS) FOR 230 VAC
8.0A (RMS) FOR 115 VAC
INRUSH CURRENT: 30A MAX. FOR 115 VAC PER MODULE
60A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC CAN REACH THE
TARGET OF 95% AT 230V, FULL LOAD

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0.5 32 ±5% ±1% 50mV
+12V 2.0 45 ±5% ±1% 120mV
-12V 0 0.8 ±10% ±1% 120mV
+3.3V 0.5 25 ±5% ±1% 50mV
+5VSB 0.1 3.5 ±5% ±1% 50mV
* +5V AND +3.3V TOTAL OUTPUT MAX: 170W
* TOTAL OUTPUT MAX: 550W

FEATURES

* TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
* EFFICIENCY: THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 80%, MEASURED AT NOMINAL INPUT VOLTAGE 230 V AND FULL LOADING.
* LEAKAGE CURRENT: 3.5MA. MAX AT NOMINAL VOLTAGE 240VAC
* REMOTE ON/OFF CONTROL
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1ms
* OVER POWER PROTECTION: 110~160%
* OVER VOLTAGE PROTECTION: +5V→5.7V~6.7V, +3.3V→3.9~4.7V, +12V→13.3~16.5V
* OVER CURRENT PROTECTION: +3.3V. +5V. +12V → 110~160%
* SAFETY: TO MEET UL/CUL, TUV, CB, CCC
* EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module