OUTPUT WATTAGE

320W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

185x150x86(mm)

7.28x5.91x3.39(inch)

INPUT SPEC

VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 Hz
INPUT CURRENT: 5/3A @ 115 / 230 VAC
INRUSH CURRENT: 25/50 AMPS @115/230 VAC
(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
95% @ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC
1000-3-2

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1.0 25 ±5% ±1% 50mV
+12V 1.0 26 ±5% ±1% 120mV
-12V 0 0.5 ±5% ±1% 150mV
+3.3V 1.0 20 ±5% ± 1% 50mV
+5VSB 0.1 3 ±5% ±1% 50mV
* +5V AND +3.3V MAX. POWER: 150W
* TOTAL POWER: 320W (MAX)

FEATURES

* TEMPERATURE RANGE : OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
* EFFICIENCY: THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 87.8%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING.
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OUTPUT PROTECTION: OPP / OVP / OCP / SCP
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
* BALANCE LOAD SHARING DESIGN
* REMOTE ON/OFF CONTROL
* LEAKAGE CURRENT: 3.5mA. RMS. MEASUREMENT WILL BE MADE AT 240VAC AND 60HZ
* ISOLATION: BUILT-IN IN THE POWER MODULE

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 