Products

1U RedundantR1S2-5120V0H


 

OUTPUT WATTAGE

120W

BEST SOLUTION FOR

Server ,Workstation ,Storage System

DIMENSION

150x176x41.8(mm)

5.91x6.93x1.65(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE
70A MAX. FOR 230 VAC PER MODULE

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 10 ±5% ±1% 50mV
+12V 2 10 ±5% ±1% 120mV
-12V 0 0.3 ±5% ±1% 120mV
+3.3V 0 10 ±5% ±1% 50mV
+5VSB 0.1 3 ±5% ±1% 50mV
* POWER MODULE TOTAL OUTPUT POWER OF +3.3V AND +5V NOT EXCEED 80W
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 120W

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:TYPICAL 85% AT 230V, 50% OF FULL LOAD
* LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.1V, +12V→12.8~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY: MEET UL&CUL, TUV
* WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 