Products

2U SingleBP2H-5460V


 

OUTPUT WATTAGE

460W

BEST SOLUTION FOR

Server ,Workstation ,IPC ,Communication

DIMENSION

215x100x70(mm)

8.46x3.94x2.76(inch)

INPUT SPEC

VOLTAGE: DC 18V~36V
INPUT CURRENT:18~36VDC / 35~18AMP (26A (RMS) FOR 24 VDC)
INRUSH CURRENT:50 AMPS @24VDC(AT 25 DEGREES AMBIENT COLD START)

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 25 ± 5% ± 50mV 50mV
+12V 2 37 ± 5% ± 50mV 120mV
-12V 0 0.8 ± 5% ± 50mV 120mV
+3.3V 0 25 ± 5% ± 50mV 50mV
+5VSB 0.1 3 ± 5% ± 50mV 50mV
+5V AND +3.3V TOTAL OUTPUT MAX: 170W
TOTAL OUTPUT MAX: 460W

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 1.6 MSEC AT 24V
* EFFICIENCY:>80% TYPICAL AT 24V, FULL LOAD
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
* OVER POWER PROTECTION: 110~150%
* OVER VOLTAGE PROTECTION: +5V→5.6~6.5V, +3.3V→3.6~4.3V, +12V→13.2~15V
* OVER CURRENT PROTECTION: +3.3V→27.5~37.5A, +5V→27.5~37.5A, +12V→40.7~55.5A
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* EMI NOISE FILTER : FCC CLASS A, CISPR22 CLASS A
* SAFETY: TO MEET UL, TUV, CB
* COOLING: 60mm DC FANS


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module