【1U Single】H1M-5807V
800W
Server ,Workstation ,Storage System
275x100x40.5(mm)
10.83x3.94x1.59(inch)
VOLTAGE: 90~264 VAC FULL RANGE FREQUENCY: 47 ~ 63 HZ INPUT CURRENT: 12A / 6A AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT: 40.0A MAX. FOR 115 VAC / 60.0A MAX. FOR 230 VAC (AT 25 DEGREES AMBIENT COLD START)
* TEMPERATURE RANGE: OPERATING 0℃ --- 50℃, STORAGE –20℃ --- 80℃ * HOLD UP TIME: 16 ms MINIMUM AT 115AC INPUT; 20ms MINIMUM AT 230 AC INPUT * EFFICIENCY: TYPICAL >80% AT 115V FULL LOAD * PFC CAN REACH THE TARGET OF 95% AT 115V/230VAC, FULL LOAD * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms * OVER POWER PROTECTION: 110%~160% * OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V * OVER CURRENT PROTECTION: +3.3V→27.5~40A, +5V→27.5~40A, +12V→52.8~72A (800W—62.7~87A) * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * SAFETY: TO MEET UL, CUL, TUV, CCC * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B * 3.5MA MAX. AT NOMINAL VOLTAGE VAC *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module