Products

Open FrameQ1J-1060V-12


   

OUTPUT WATTAGE

60W

BEST SOLUTION FOR

Server ,Workstation ,Storage System

DIMENSION

103x52x39(mm)

4.06x2.05x1.54(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:1.5A (RMS) FOR 115 VAC /
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC /
70A MAX. FOR 230 VAC

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+12V 0 5 ±5% ±1% 120mV

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~70℃, STORAGE –20℃~80℃
* HOLD UP TIME: WHEN AC SOURCE SHUTDOWN DC OUTPUT MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE(AC115V AT 80% OF FULL LOAD)
* EFFICIENCY:85% (+/-2%) AT 115VAC/230VAC AND LOAD CONDITION: 12V/5A
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1mS
* OVER POWER PROTECTION: 110~160% (AC 100V~240V)
* OVER VOLTAGE PROTECTION: +12V→13.2V~15.0V
* SHORT CIRCUIT PROTECTION: +12V
* LEAKAGE CURRENT: 3.5MA MAX. AT NOMINAL VOLTAGE 264VAC
* SAFETY: TO MEET UL&CUL, TUV, CCC

*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module