Products

PS2HU2-5660V


   

OUTPUT WATTAGE

660W

BEST SOLUTION FOR

Server ,Workstation ,Storage System

DIMENSION

150x140x86(mm)

5.91x5.51x3.39(inch)

INPUT SPEC

VOLTAGE:90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:10.0A (RMS) FOR 115 VAC / 5.0A (RMS) FOR 230 VAC
INRUSH CURRENT:20A MAX. FOR 115 VAC / 40A MAX. FOR 230 VAC
PFC CAN REACH THE TARGET OF 95% @230VAC, FULL LOAD

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0.5 25 ±5% ±1% 50mV
+12V 1.0 50 ±5% ±1% 120mV
-12V 0 0.8 ±5% ±1% 120mV
+3.3V 0.5 25 ±5% ±1% 50mV
+5VSB 0.1 3.5 ±5% ±1% 50mV

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~50℃
* HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 SECOND, INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
* EFFICIENCY:TYPICAL 80-85% AT 25℃ 115V FULL LOAD
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
* OVER POWER PROTECTION:TRIP POINT TOTAL POWER MIN. 110%, MAX. 150%
* OVER VOLTAGE PROTECTION:+5V→5.8V~6.7V, 3.3V→3.6V~4.3V, +12V→13.2V~15V
* SHORT CIRCUIT PROTECTION:+5V、-5V、+12V、-12V、+3.3V
* RESTART AFTER PROTECTION
* EMI NOISE FILTER : FCC CLASS B , CISPR22 CLASS B
* SAFETY : UL, CUL, TUV, CCC
* REMOTE ON/OFF CONTROL: THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL. DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.

*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module