Products

2U SingleP2G-5500V


   

OUTPUT WATTAGE

500W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

240x100x70(mm)

9.45x3.94x2.76(inch)

INPUT SPEC

VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY: 47 ~ 63 HZ
INPUT CURRENT: 8.0A ( RMS ) FOR 115VAC, 4.0A ( RMS ) FOR 230 VAC
INRUSH CURRENT: 25A MAX. FOR 115 VAC, 50A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET
OF 95% AT 115/230VAC, FULL LOAD

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0.5 25 ±5% ±1% 60mV
+12V 0.5 40 ±5% ±1% 120mV
-12V 0 0.8 ±5% ±1% 120mV
+3.3V 0.5 25 ±5% ±1% 60mV
+5VSB 0 3.5 ±5% ±1% 60mV

FEATURES

‧TEMPERATURE RANGE: OPERATING 0℃ --- 50℃, STORAGE –20℃ --- 80℃
‧HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
‧EFFICIENCY: 80~83% TYPICAL AT 115V, FULL LOAD
‧LEAKAGE CURRENT: 3.5mA MAX. AT NOMINAL VOLTAGE VAC ‧POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
‧OVER POWER PROTECTION
‧OVER VOLTAGE PROTECTION
‧OVER CURRENT PROTECTOIN
‧SHORT CIRCUIT PROTECTION
‧EMI: FCC CLASS B, CISPR22 CLASS B
‧SAFETY: TO MEET UL, CUL, TÜV, CCC
‧COOLING: ONE 60mm DC FAN
‧MEET IEC-1000-3-2 CLASS D


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module