Products

1U SingleH1U-5300V


   

OUTPUT WATTAGE

300W

BEST SOLUTION FOR

Server ,Workstation ,Storage System ,IPC

DIMENSION

155x100x40.5(mm)

6.1x3.94x1.59(inch)

INPUT SPEC

VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 4.0 A ( RMS ) FOR 115VAC /
2.0 A ( RMS ) FOR 230VAC
INRUSH CURRENT: 20A MAX. FOR 115 VAC /
40A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE
TARGET OF 95% @115V, FULL LOAD, FOLLOWING THE STANDARD

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1 18 ±5% ±1% 50mV
+12V 1 22 ±5% ±1% 120mV
-12V 0.1 0.5 ±10% ±1% 120mV
+3.3V 1 16 ±5% ±1% 50mV
+5VSB 0.1 2 ±5% ±1% 50mV
* +5V AND +3.3V TOTAL OUTPUT MAX: 25A
* +5V, +3.3V, +12V TOTAL MAX: 284W
* TOTAL POWER: 300W

FEATURES

* TEMPERATURE RANGE: OPERATING 0℃ --- 40℃, STOREAGE -20℃ --- 80℃
* HOLD UP TIME: WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16mSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY: 80%-84% TYPICAL AT 115V, FULL LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OVER POWER PROTECTION
* OVER VOLTAGE PROTECTION
* SHORT CIRCUIT PROTECTION
* EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* SAFETY: UL, TÜV, RFI/EMI STANDARDS
* COOLING: ONE 40mm DC FANS


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:emacs,zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module