Products

CRPS RedundantZRH2-5AF0K2H


OUTPUT WATTAGE

1600W

BEST SOLUTION FOR

DIMENSION

260x153x41.3(mm)

0x0x0(inch)

INPUT SPEC

"VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:10.5A (RMS) FOR 110 VAC /8.5A (RMS) FOR 220 VAC
INRUSH CURRENT:35A MAX.(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 99% @230V, FULL LOAD.( ONE UNIT POWER SUPPLY).
"

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 32 ±5% ±1% 50mV
+12V 0 "133A(high line)83A(low line)" ±5% ±1% 120mV
3.3V 0 25 ±5% ±1% 50mV
-12V 0 0.5 ±10% ±1% 120mV
+5VSB 0 3.5 ±5% ±1% 50mV
* +5V AND +3.3V Max. POWER: 180W

FEATURES

"* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -40℃~70℃
* HOLD UP TIME:WHEN POWER SHUTDOWN ALL THE DC OUTPUT VOLTAGE MUST BE MAINTAIN 10mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE(70%LOAD)
* THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 86%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING (one power unit).
* LEAKAGE CURRENT: 3.5mA. MAX. AT NOMINAL VOLTAGE 240 VAC AND 60Hz
* REMOTE ON/OFF CONTROL
* OVER POWER PROTECTION:110~160% MAX
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.3V, +12V→13.5~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* OVER CURRENT PROTECTION: +12V:110~165%
* SAFETY: MEET 60950 UL&CUL, TUV, CCC ,UL/EN/IEC 62368
* WARNING METHOD: FALUT LED, TTL
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
"

 

keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module