Products

MedicalMHG2-5400G


 

OUTPUT WATTAGE

400W

BEST SOLUTION FOR

Server ,Workstation ,PCs

DIMENSION

140x150x86(mm)

5.51x5.91x3.39(inch)

INPUT SPEC

VOLTAGE: 100~240VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:6A (RMS) FOR 115 VAC / 3A (RMS) FOR 230 VAC. INRUSH CURRENT:20A MAX. FOR 115 VAC / 40A MAX. FOR 230 VAC(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT) PFC: UP TO THE TARGET OF 95%@110V

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 15 ±5% ±1% 50mV
+12V 0 33 ±5% ±1% 120mV
-12V 0 0.5 ±10% ±1% 120mV
+3.3V 0 15 ±5% ±1% 50mV
+5VSB 0 3 ±5% ±1% 50mV
(1) +5V and +3.3V total output max : 100W (2) Total power :400W Note: For dynamic voltage regulation requirements +12V min Loading is 1A

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN ALL THE DC OUTPUT VOLTAGE MUST BE MAINTAIN 16mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE (70% LOAD) * THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 87%, MEA

 