Products

Micro RedundantR1U2-5220V4H


   

OUTPUT WATTAGE

220W

BEST SOLUTION FOR

Server ,Workstation ,Storage System

DIMENSION

260x106x41.3(mm)

10.24x4.17x1.63(inch)

INPUT SPEC

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A(RMS)FOR 230VAC
4A(RMS)FOR 115VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE
70A MAX. FOR 230 VAC PER MODULE

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 16 ±5% ±1% 50mV
+12V 0.1 17.5 ±5% ±1% 120mV
-12V 0 0.3 ±10% ±1% 120mV
+3.3V 0 16 ±5% ±1% 50mV
+5VSB 0.1 2 ±5% ±1% 50mV
* +5V AND +3.3V TOTAL OUTPUT MAX: 120W

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~50℃,STORAGE -20℃~80℃
* HOLD UP TIME:20mS MIN. AT FULL LOAD & 115 VAC INPUT VOLTAGE
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE
* EFFICIENCY:TYPICAL 78%(+/-2%) AT FULL LOAD 230VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 600mS,OFF DELAY 1mS
* OVER POWER PROTECTION:110~170% MAX
* OVER VOLTAGE PROTECTION:+3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V
* SAFETY:TO MEET UL, CUL, TUV, CCC
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)


* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 

keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module