Products

PS2+GU2-5A50V


   

OUTPUT WATTAGE

1050W

BEST SOLUTION FOR

Server ,Workstation ,Storage System

DIMENSION

160x150x86(mm)

6.3x5.91x3.39(inch)

INPUT SPEC

VOLTAGE:90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:14 (RMS) FOR 120 VAC / 7A (RMS) FOR 230 VAC
INRUSH CURRENT:40A MAX. FOR 120 VAC / 80A MAX. FOR 230 VAC
PFC CAN REACH THE TARGET OF 95% @230VAC, FULL LOAD

DC OUTPUT SPEC

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0.5 34 ±5% ±1% 50mV
+12V 1 85 ±5% ±1% 50mV
-12V 0 0.8 ±5% ±1% 120mV
+3.3V 0.5 34 ±5% ±1% 50mV
+5VSB 0.1 3.5 ±5% ±1% 50mV
TOTAL POWER: 1050W(MAX) +5V AND +3.3V TOTAL MAX.: 55A

FEATURES

* TEMPERATURE RANGE:OPERATING 0℃~40℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 12mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:TYPICAL 80-85% AT 25℃ 115V FULL LOAD
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
* OVER POWER PROTECTION:TRIP POINT TOTAL POWER MIN. 110%, MAX. 150%
* OVER VOLTAGE PROTECTION:+5V→5.8V~6.7V, 3.3V→3.6V~4.3V, +12V→13.2V~15V
* OVER CURRENT PROTECTOIN: +3.3V→37.4~51A, +5V→37.4~51A, +12V→93.5~127A
* SHORT CIRCUIT :+5V、-5V、+12V、-12V、+3.3V
* RESTART AFTER PROTECTION
* LEAKAGE CURRENT: 1.5MA MAX. AT NOMINAL VOLTAGE VAC
* EMI NOISE FILTER : FCC CLASS B , CISPR22 CLASS B
* SAFETY : TO MEET UL, CUL, TUV, CCC
* REMOTE ON/OFF CONTROL


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 